INSTALLATION INSTRUCTIONS- RCL100, 120, 130 AND 180 SERIES RESERVOIR, CONSTANT LEVEL - ADJUSTABLE, SIDE & BOTTOM OUTLET

Step 1. Disassemble reservoir as shown. You will have 5 separate parts.

1a. Reservoir bowl assembly.
1b. Adjustment body.
1c. Lock nut.
1d. Constant level chamber.
1e. Pipe plug (RCL 130 and 180 only).

CAD drawing
Step 2.   (RCL 130 and 180 only)

Determine outlet side to be used. Tighten pipe plug into unused outlet (FIG 2).

CAD drawing
Step 3.
Use a nipple for side outlet or combination of nipples and elbows for bottom outlet to achieve minimum oil level in bearing housing. I.D. of pipe must be deburred as well as pipe tap on bearing housing to remove all burrs, hanging particles, etc (FIG 3).

CAD drawing
Step 4.
Make sure tapped hole in bearing housing (FIG 4) is tapped square to face so that nipple will be in a horizontal plane. Top of tap drill should be equal to oil level to be maintained.

CAD drawing
Step 5.
Use teflon filled pipe dope, not tape on threaded ends of nipple/pipe. Tape can break off into tiny shavings, thus contaminating bearing of shaft and will result in machine failure.

Tighten nipple into bearing housing (5a) using wrench or pliers to tighten.

Use open end wrench to tighten lower base (5b) onto nipple. Wipe excess pipe dope off threads.

CAD drawing
Step 6.
Invert reservoir to fill through spout (FIG 6). When full hold thumb over spout, invert over base and screw in finger tight. You may prefill, but final oil level must be established by spout on reservoir.

CAD drawing
Step 7.
Check all joints for leaks and determine that oil is up to desired level (FIG 7). Units are shipped with .22 minimum fill level. To raise the fill level, back off the adjustment body (1b) to the desired level, and turn the locknut (1c) to lock body in place.

CAD drawing


Home | Products | Typical Applications | News
Vescor Hydraulic Reservoirs | Flodar Hydraulic Fittings | Hydra-Tool Rotary Manifolds
Contact Us | Sitemap

LDI Industries, Inc.
1864 NAGLE AVE., P.O. BOX 1810
MANITOWOC, WI 54221
PHONE: (920) 682-6877
FAX: (920) 684-7210

Copyright © Lube Devices, Inc.  
All Rights Reserved. Privacy Statement